Is the OZONOS® Aircleaner dangerous? Ozone levels, limit values and TÜV testing: a fact check

The short answer: Yes, ozone generators can be dangerous.
The OZONOS® Aircleaner is not one of them. A conventional ozone generator typically produces more than 1,000 mg of ozone per hour and may only be operated in empty rooms.
Depending on the model, the OZONOS® produces 2.5 to 12 mg/h — up to 400 times less. Both device generations are certified by TÜV SÜD according to EN 60335-2-65 (view certificates); at 0.05 ppm, this standard sets the strictest applicable ozone limit. In real living spaces, 0.012 to 0.015 ppm were measured during continuous operation.

Anyone searching for “air purifiers with ozone” quickly comes across clear warnings — from environmental agencies, consumer portals and trade media. These warnings are justified. On closer inspection, however, they almost always refer to a device category the OZONOS® does not belong to.

This article separates the two: with measured values, applicable standards, verifiable certificate numbers and clearly stated limits of use.

At the end, you will find a guide to which model suits which room.

Frequently asked questions

No. Both device generations are certified by TÜV SÜD according to EN 60335-2-65 — the standard with the strictest applicable ozone limit of 0.05 ppm, measured directly at the device in continuous operation under deliberately unfavorable conditions. In real living spaces, 0.012 to 0.015 ppm were measured.

No. Ozone generators produce ozone using high voltage, usually emit more than 1,000 mg/h and also produce nitrogen oxides that are harmful to health. They may only be operated in empty rooms. The OZONOS® produces ozone using UV-C radiation, emits 2.5 to 12 mg/h depending on the model and produces no nitrogen oxides.

The AC I holds certificate Z1 110331 0005 Rev. 00 (test report 713376048-1, valid until September 3, 2030), the AC II certificate Z1 110331 0002 Rev. 00 (test report 713335709, valid until June 1, 2030). Both were tested by TÜV SÜD Product Service GmbH according to EN 60335-1 and EN 60335-2-65 in version A12:2022. The numbers can be independently verified in the TÜV SÜD certificate database.

A Standard version produces 2.5 mg of ozone per hour, a Pro version up to 12.0 mg/h. In measurements, the resulting room concentration was 0.012 ppm (72 m³ open-plan kitchen) to 0.015 ppm (15 m³ bathroom after six hours of continuous operation).

EN 60335-2-65 is applied, with 0.05 ppm — the strictest of the relevant values. It is met, as certified by TÜV SÜD. This also means the EU target value (0.06 ppm) and the occupational safety limits (0.10 ppm daily average) are met.

With the Standard version, yes, continuously. The Pro version is an intensive cleaner and is not intended for continuous operation with people permanently present.

In very small, enclosed and unventilated spaces under about 4 m² — windowless toilets, driver’s cabs, vehicle interiors — ozone can accumulate to the point where longer stays should be avoided. There, let the device run, but do not occupy the room, and ventilate afterwards. This restriction does not apply to normal-sized rooms.

This recommendation applies to Pro devices and is derived from a worst-case assumption: a Pro device in continuous operation in a room of 4 m² or less without ventilation. So the real limit is not operating time, but room size. The Standard version is built for continuous presence in occupied rooms.

Two questions decide. First: do you stay in the room for long periods while the device is running? Then Standard. Is it about strong odors and targeted cleaning? Then Pro. Second: should the device run automatically at set times — before cooking, during office hours? Then the OZONOS® AC II. Is switching on and off enough? Then the OZONOS® AC I.

A Pro device; for open-plan kitchens of up to 50 m², we recommend the AC II Pro. Cooking odors are the highest load in the household, and scheduling is a perfect fit here: start 15 minutes before cooking, let it run on afterwards, switch off automatically.

A Standard version. It is designed for continuous operation while people are present. A Pro device does not belong in the bedroom.

A Standard version, because you spend hours in the same room. The AC II Standard offers the added advantage that the device runs automatically during office hours.

The AC II covers rooms of up to 50 m². For the AC I: Standard up to 30 m², Pro up to 50 m². For open floor plans or multiple rooms, a second device makes more sense than one operating at its limit.

The lamp strength and therefore the ozone output: Standard 2.5 mg/h, Pro up to 12.0 mg/h. Standard is designed for continuous basic cleaning while people are present and may run continuously. Pro is used for fast, intensive cleaning under heavy odor load.

The AC I Classic is operated directly on the device, the AC II Smart additionally via a PWA with timers and schedules. Technically, they differ in their power supply: AC I with 220–240 V~ and 14 W in protection class I, AC II with 12 V safety extra-low voltage and 9 W in protection class II. This choice has no influence on the safety rules.

The same rules apply to children and pets as to adults: Standard versions are safe in continuous operation; during intensive cleaning with Pro devices, do not occupy the room. Plants are considerably more resistant; the EU limits for the protection of vegetation are 3.00 to 9.00 ppm.

Possibly, slightly. Ozone is perceptible from 0.0076 to 0.03 ppm — far below the limit of 0.05 ppm. A distinct or pungent smell only occurs from about 0.10 ppm. If you clearly smell ozone, switch the device off.

In real living spaces, the ozone concentration halves every 8 to 15 minutes; under the unfavorable conditions of the standard, it takes 62 minutes. Rule of thumb with a large safety margin: one hour after switching off, even a small room can be entered without concern.

People with asthma or COPD have been shown to react more sensitively to ozone. We recommend discussing use with your doctor. If you decide on a device: choose a Standard version, not a Pro.

No, not to any measurable extent. One cubic meter of air contains around 252,000 mg of oxygen; a Pro device turns 12 mg of it into ozone per hour — 0.005%.

No, quite the opposite. An aging UV-C lamp produces less ozone. The highest concentration occurs with a new lamp — in the tested and certified condition.

Not mechanically. Ozone does not filter; it oxidizes. It acts on organic substances — odors, germs, viruses, bacteria, pollen, mold spores — and on the organic components of dust, not on the particle mass itself.

Conclusion

Skepticism about ozone indoors is scientifically justified, and blanket reassurances help no one. The warnings about “ozone devices” refer to devices that release more than 1,000 mg of ozone per hour, produce nitrogen oxides in the process and whose concentrations in the room can hardly be controlled.

The OZONOS® belongs to a different category. It produces 2.5 to 12 mg/h, generates no by-products, complies with the strictest applicable limit of 0.05 ppm and is externally certified for this in both device generations — verifiable in the TÜV SÜD certificate database or directly in the certificates for AC I and AC II.

That does not mean there are no rules. Pro devices are intensive cleaners and are not intended for permanent presence. Very small, enclosed spaces are the real limit of use — there, the rule is: let the device run, do not occupy the room, ventilate afterwards. Sensitive individuals should consult their doctor. And choosing a model is not a question of “more is better”, but of “right for the room and the use”.

We state these limits because they are part of the answer.